Lower incisor extraction therapy in a complex case with an ankylosed tooth in an adult patient: A case report

Int Orthod. 2020 Dec;18(4):850-862. doi: 10.1016/j.ortho.2020.08.006. Epub 2020 Sep 15. ABSTRACT This case report describes a successful orthodontic therapy of an adult female treated by mandibular central incisor extraction and vestibular fixed appliances. The patient presented a skeletal Class I with normodivergent facial pattern, Class II subdivision dental relationship, extremely deep Curve of Spee and…

Clear aligner hybrid approach: A case report

J World Fed Orthod. 2020 Mar;9(1):32-43. doi: 10.1016/j.ejwf.2020.01.001. Epub 2020 Feb 12. ABSTRACT INTRODUCTION: This case demonstrates that hybrid application of clear aligners can be a rational and efficient approach for treating malocclusions, as compared with a clear aligner therapy alone option in which the magnitude of some movements would require a higher number of…

Fluorescence-aided composite removal during lingual bracket debonding

J Esthet Restor Dent. 2020 Oct;32(7):634-637. doi: 10.1111/jerd.12618. Epub 2020 Jul 9. ABSTRACT OBJECTIVE: This report describes the fluorescence-aided composite removal during lingual bracket debonding with an ultraviolet light emitting diode flashlight. The purpose of this technique is to help clinicians in composite removal without enamel surface damage. CLINICAL CONSIDERATIONS: The bracket debonding requires clinical…

Early class III treatment with hybrid rapid palatal expander combined with facemask

Int Orthod. 2020 Sep;18(3):624-635. doi: 10.1016/j.ortho.2020.05.002. Epub 2020 Jun 10. ABSTRACT BACKGROUND: Class III patients are characterized by a deficiency of the maxilla and/or a prognathism of the mandible and require early treatment. DIAGNOSIS: This case report describes the treatment of a 5-year-old patient with a skeletal class III relationship, a significant mandibular symphysis deviation…

MicroCT X-ray comparison of aligner gap and thickness of six brands of aligners: an in-vitro study

Prog Orthod. 2020 May 11;21(1):12. doi: 10.1186/s40510-020-00312-w. ABSTRACT BACKGROUND: To investigate and compare the gap (i.e. fit) and thickness of six aligner systems (Airnivol, ALL IN, Arc Angel, F22, Invisalign and Nuvola) using industrial computed tomography (CT). The null hypothesis was that there would be no detectable differences in either measurement between the aligners investigated.…

Comparison of the accuracy of digital face scans obtained by two different scanners

Angle Orthod. 2021 Sep 1;91(5):641-649. doi: 10.2319/092720-823.1. ABSTRACT OBJECTIVES: To compare the degree of accuracy of the Face Hunter facial scanner and the Dental Pro application for facial scanning, with respect to both manual measurements and each other. MATERIALS AND METHODS: Twenty-five patients were measured manually and scanned using each device. Six reference markers were…

Association of the mid-palatal suture morphology to the age and to its density: A CBCT retrospective comparative observational study

Int Orthod. 2021 Jun;19(2):235-242. doi: 10.1016/j.ortho.2021.03.002. Epub 2021 Mar 27. ABSTRACT OBJECTIVE: The twofold aim of the present investigation was to: 1. evaluate the degree of mid-palatal suture (MPS) maturation via CBCT in relation to patient age, and 2. to determine whether there was a correlation between quantitative (i.e., suture density) and qualitative (i.e., suture…

Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study

Korean J Orthod. 2021 Mar 25;51(2):135-141. doi: 10.4041/kjod.2021.51.2.135. ABSTRACT OBJECTIVE: To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness. METHODS: Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To…