Accuracy of Curve of Wilson Levelling and Posterior Tooth Inclination With Vestibular, Lingual Straight Wire Technique and Clear Aligners: A Retrospective Cohort Study

Orthod Craniofac Res. 2026 Jul 6. doi: 10.1111/ocr.70165. Online ahead of print. ABSTRACT OBJECTIVE: To evaluate the discrepancy between programmed and achieved posterior tooth inclination and to assess the accuracy of Curve of Wilson levelling and posterior tooth inclination in the mandibular arch across three different techniques: vestibular fixed appliance, lingual fixed appliance and aligners.…

AI text detection in dentistry: a comparative analysis across generative models

Res Integr Peer Rev. 2026 Jun 9. doi: 10.1186/s41073-026-00228-9. Online ahead of print. ABSTRACT BACKGROUND: Robust screening for AI-generated scientific text is increasingly required by journals, yet detector performance on full-length manuscripts remains unclear. Six widely used detectors were benchmarked on dentistry manuscripts, and performance was compared across state-of-the-art generators. METHODS: A total of 120…

CBCT-based simulation of mandibular buccal shelf miniscrew insertion: Influence of angulation, facial pattern, sex and side on simulated miniscrew trajectory length: A retrospective study

Int Orthod. 2026 Apr 24;24(3S):101173. doi: 10.1016/j.ortho.2026.101173. Online ahead of print. ABSTRACT AIM: To evaluate simulated miniscrew trajectory length in the mandibular buccal shelf (MBS) area in order to identify the most suitable site for miniscrew placement at different insertion angles. Effects of side, sex, and facial pattern were also investigated. MATERIALS AND METHODS: Cone-beam…

Factors influencing the accuracy of guided palatal miniscrew insertion in young adults : Prospective in vivo study

J Orofac Orthop. 2026 Mar 3. doi: 10.1007/s00056-026-00650-0. Online ahead of print. ABSTRACT OBJECTIVE: To evaluate the in vivo accuracy of guided palatal miniscrew insertion, focusing on the effect of insertion side, frontal insertion angle, and miniscrew length. MATERIALS AND METHODS: In all, 52 palatal miniscrews were inserted using computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides…

Accuracy of a clear aligner hybrid approach in managing severe rotations of rounded teeth : A retrospective cohort study

J Orofac Orthop. 2026 Jan 29. doi: 10.1007/s00056-025-00638-2. Online ahead of print. ABSTRACT AIM: The aim of this retrospective study was to evaluate the accuracy of rotational movements of maxillary and mandibular canines and premolars achieved using clear aligners combined with a segmental lingual appliance, as planned in the digital setup, and to compare these…

Anchorage control with mandibular miniscrews in an adult severe high-angle Class II case treated by preadjusted lingual appliance, premolar extractions and orthognathic surgery

Int Orthod. 2025 Dec 24;24(2S):101113. doi: 10.1016/j.ortho.2025.101113. Online ahead of print. ABSTRACT This case report describes a complex full-step Class II high-angle case in an adult patient treated with lingual straight-wire appliance, premolar extractions and orthognathic surgery. With the twofold aim of obtaining ideal occlusal relationship and aesthetic improvement, surgical treatment with appropriate biomechanical strategies,…

Lower incisors decompensation by torque auxiliary spring for an adult high-angle Class III extraction camouflage with preadjusted lingual appliance: A case report

Int Orthod. 2025 Dec 24;24(2S):101111. doi: 10.1016/j.ortho.2025.101111. Online ahead of print. ABSTRACT This case report describes a complex Class III high-angle case in an adult patient treated with preadjusted lingual appliance and premolar extractions. With the twofold aim of obtaining aesthetic improvement and ideal occlusal relationship, accurate set-up planification and linear biomechanical strategies, including lower…